Certified New York Parapet inspections

Please refer to the Home Inspection Standards of Practice while reading this inspection report. I performed the home inspection according to the standards and my clients wishes and expectations. Please refer to the inspection contract or agreement between the inspector and the inspector’s client.

Beginning on January 1, 2024, every building owner must have an observation of the parapet on their building(s) performed in accordance with the requirements of Section 28-301.1.1 of the New York City Administrative Code. This requirement applies to all buildings with parapets fronting the public right-of-way, regardless of height. EXCEPT: Detached 1- or 2- family homes or buildings with a fence or other barrier preventing access to the exterior wall.

The observation must include close-up inspections of the entire parapet which could be conducted from a fire escape or roof. See 1 RCNY §103-15 for more information on observation and report requirements.

Owners must maintain the observation reports for at least six (6) years and must make such reports available to the Department upon request.

Observations must be performed annually by a person competent to inspect parapets, including, but is not limited to a bricklayer, building superintendent, handyman, mason or a person in a similar construction-related trade, architect, engineer, an inspector working for a New York State-authorized insurance company, a New York State-authorized building inspector, or any other individual capable of identifying hazards on the parapet.

The observation must include, but not be limited to: a determination that the parapet is plumb by a horizontal distance within one-eighth of its cross-sectional thickness in any location a determination of whether there is excessive deterioration, including, but not limited to, displacement, horizontal or diagonal cracks, missing or loose bricks or coping stones, deteriorated mortar joints, spalling, or rot a determination that appurtenances such as telecommunications equipment, railings, roof access rails, gooseneck ladders and handrail attachments for fire escapes, and signs, have been installed and maintained in a stable condition.

The person performing the observation must immediately notify the Department of Buildings by calling 311 and emailing parapets@buildings.nyc.gov.
The owner must immediately install public protection, such as erecting a sidewalk shed, removing the unsafe condition, closing off the area with a fence, and/or installing safety netting, as may be required to secure the safety of the public, and have the unsafe condition remedied.

All unsafe conditions must be corrected within ninety (90) days from the notification to the Department. The public protection must remain in place until the unsafe condition is remedied.

The parapet inspections report must include, but not limited to, the following information:

  • the address of the property
  • the name, mailing address and telephone number of the owner of the building, or, if the owner is not an individual, the name, mailing address, telephone number, and position/title of a principal of the owner
    the name of the person performing the observation. if other than the owner, their mailing address, telephone number, affiliation with the building or owner, and business name, if applicable
    the date(s) of the observation
    the location plan of the parapet(s) observed
    the construction of the parapet, including but not limited to material, height, and thickness
    general conditions noted, whether any unsafe conditions were found, and actions taken to remedy the unsafe conditions
    any repairs made to the parapet since the previous report
    dated photos documenting the conditions at the time of observation.

INSPEXTRO

Parapet Inspections

Call us today at 631-560-5803 to schedule a complimentary estimate! Why wait? We aim to be your one-stop solution for all your inspection needs. Contact INSPEXTRO today, and let us take the hassle out of your home inspections.

Schedule Now

We’re proud to provide easy, online, and flexible scheduling!

Local knowledge · Regional reach

See where we inspect.

From New York City to Long Island and Westchester, explore our service areas. Select a region on the map or choose an area below.

Service areasSelected area

Regional coverage overview. Select the borough buttons for an easier view of New York City's smaller areas.

Serving All Highlighted Areas

We serve all the areas shown above. Visit Get a Quote to check inspection fees for your property.

Check Inspection Fees

NYC annual parapet observation

Understand the requirement. Plan the visit.

A parapet is the part of a wall above the roof line. Its condition matters to people below as well as to the building. Our company can help you discuss the observation scope, access and report arrangements.

Annual observation

NYC requires annual observation for covered parapets fronting the public right-of-way, regardless of building height. Exceptions apply; confirm your building's circumstances with DOB.

By December 31

DOB's FAQ says covered buildings must have the year's observation completed and the report on file by December 31. Plan access early rather than leaving arrangements to year-end.

Keep the report

Owners retain reports for at least six years and make them available to DOB on request. Routine observation reports are not submitted to DOB; unsafe-condition notifications are separate.

Review the NYC DOB Parapet FAQ for official program details. This overview helps you prepare; building-specific applicability, access and any additional services should be confirmed before booking.

Explore the details above the roof line

Small details. Important observations.

Select a numbered point or topic to explore common parapet concerns. This simplified illustration explains components; it does not assess your building.

Illustrated section · Not to scale

Coping & top edges

What is observed?

Accessible coping stones, caps, joints and roof-edge transitions are observed for visible displacement, open joints, deterioration or loose components.

Why does it matter?

Open or deteriorated top details can allow water into the wall. Displaced or loose components may present a falling-material concern that needs prompt evaluation.

What happens next?

The report documents the observed condition and recommended action. Repair needs, stabilization and any additional investigation depend on the findings and may involve a qualified masonry contractor or design professional.

Safe access and the appropriate observation method must be confirmed. Photos or a drone view alone should not be assumed to satisfy close-up observation requirements.

If material is falling or a collapse poses an immediate danger, stay clear and call 911. Do not access a suspect parapet or attempt repairs yourself. NYC safety guidance →

A smoother appointment starts here

Get your building ready for the visit.

Use this preparation checklist when speaking with our company. Mark the items you have arranged, then contact us to confirm the observation plan.

0 of 4 preparation items arranged

This is an appointment checklist, not a compliance score. Selections are not saved or sent.